Medical Waste Disposal-Equipment-Microwave Incinerator
This project has been suspended.
Our medical waste disposal equipment-Microwave Incinerator In Workshop
Clinical,hospital,organic,biological,bio-hazardous,infectious,pharmaceutical medical waste(or called healthcare waste) and other kinds of solid waste can be treated by this equipment with microwave technology.
1.Mainly features of this medical waste incinerator :
1)The treating speed is high.The treating time one time is justly more than ten minutes.
2)Operation is easy,only using electrical power,and the power is about 25kw
3)The temperature of furnace is high,arriving 1200 centigrade.
4)Realizing the pyrolysis- cracking under the no or lack oxygen status .
5)The treating result is very good -no dioxin.All solid medical waste becomes ashes.
Our microwave incinerator can fundamentally avoid many drawbacks in the process of medical waste disposal.Medical waste contains a large number of pathogenic microorganisms and chemical drugs, and the danger of virus is dozens or even hundreds of times more than municipal solid waste . At the same time,medical waste is component of much organic which is easy to rot, breed mosquitoes ,and spread diseases. In the process of medical waste management, incineration disposal is the best method for reducing the size and the harmless of waste .
Our Microwave incinerator for medical waste is composed of feeding system, microwave energy generator, ashing system, filtration system, cooling system, Plasma tail gas treatment system and discharging system.
Its operating principle is to use microwave technology, under anaerobic or hypoxic state, heat the medical waste and let its temperature rapidly raise to 1200℃ and thus it quickly crosses 200℃ –500℃ (Dioxins are much generated in this temperature range) and directly rapidly ashes the medical waste to avoid much Dioxins producing.
Then the high temperature pyrolysis gas from the chamber is collected and cooled by cycling water.As a result,mostly the heavy metal element is kept in the water.
As to the treatment for little Dioxins and others in exhaust gas, we use microwave Plasma torch system to do burning. The ions and electronics in Plasma have high energy, so they can fully break down the molecule in air and become co2 and h2o gas.
After that, using SCR system(Selective Catalytic Reduction) treatment,nitrogen oxide is get rid of.
The entire processing is full closure and harmless.
Our advantage comparing with the normal medical waste incinerator.
| Our microwave incinerator | Normal incinerator |
| | |
How to deal with the clinker. | no harm,can be directly landfilled. | First burned in melting incinerator of 1200℃ ,then landfill |
How to deal with the Dioxin in the gas? | Using microwave Plasma torch system to do Pyrolysis. | Using filtration with active carbon or others.
But at last ,the filtration material have to be burned in 1200℃ temperature |
Whether need diesel oil for second burning? | No need.Just need electric power. | Need. |
Whether need medical waste crushing machine? | NO need | Mostly need |
Whether need oxygen? | No burning room | Very need.If lack of oxygen,the burn will not be complete. |
Whether need second burning? | No need.The burning is completely | Need,if not,the burning will not fully. |
Whether the processing is complicated ?
| No.Modular design.Easy control | Yes.Process is complicated. |
Technical Specifications :
Dimensions (L-W-H) | 7000×4000×3000 mm |
Net weight | about 8000 kg |
Capacity | ≥1 ton/day |
Microwave frequency | 915MHz±25MHz , 2450MHz±25MHz |
Microwave power | 20kW/915MHz ,15kW/2450MHz |
Microwave Leakage | ≤5mW/㎝² |
Ashing temperature | 1200 ℃ |
Environmental indicators: gas emissions should in line with national standards “Hazardous waste incineration pollution control standards.”
Gas emissions for this medical waste disposal
Item | Value |
Dirt(mg/sm3) | 20.76
|
SOx(ppm)
| None check out |
NOx (mg/Nm3)
| 249 |
CO(ppm)
| 103.00
|
HCl (ppm)
| 1.12
|
NH3 (ppm)
| 0.63
|
H2S(ppm)
| 0.679
|
Cl2(ppm)
| None check out |
HCHO(ppm)
| 0.02
|
Note:
1. 1mg/sm3 means every 1m3 ,there is 1mg
2. 1ppm means every 1m3 ,there is 1 cm3 for gas |